Power loss - Power loss

Initial Report

Report Text:

There was a loss of main power for approxi – mately 10 seconds whilst the vessel was manoeuvring towards the berth. From the investigation that was carried out the following was noted:

Corrective/Preventative Action: The incident report was circulated to all fleet vessels with an instruction for it to be discussed with the onboard engineers and electricians. Upon receipt of the report the Chief Engineers of all fleet vessels were tasked in future to check with the subject bunker (West African) supply terminals and confirm that their tanks and products are clean and tight. The incident report will be presented and analysed by engineers during the in-house ERM training courses.

Lessons Learned:

CHIRP Comment:

The ship manager should have advised the ship to take extra and special precautions in the event of off-specification bunkers being loaded, these instructions should be in the SMS but in the event this is not the case, written instruction to the ship should have been provided. Owners could also encourage the fuel suppliers to use a service such as LR FOBAS, to assist them improve the quality of fuel.