H2S Incident - H2S Incident

Initial Report

Outline:

The following report highlights a near miss with H2S.

 

Initial Report:

A tank inspection was being carried out on board a tanker on completion of discharge. The inspection involved the Chief Officer, cargo inspector and an AB – they were checking tanks with a portable (closed type) gauging tape, which is achieved through a vapour lock arrangement.

 

At 5P COT the AB opened the vapour lock valve without checking if the cap was securely screwed on or manually holding the cap in place. The inert gas pressure inside the tank (about 500 mm/wg) ejected the cap and detached it from the safety chain to a height of about 50cm, nearly hitting the AB in the face and releasing cargo vapours on deck with H2S content of 700ppm. Fortunately, nobody was injured.

 

CHIRP Comment:

The members of the MAB noted the following points:

 

Report Ends………..

CHIRP Comment